Basic information Uses Application Safety Supplier Related
ChemicalBook >  Product Catalog >  Analytical Chemistry >  Analysis reagents >  General Analytical Reagents >  POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE

POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE

Basic information Uses Application Safety Supplier Related

POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE Basic information

Product Name:
POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE
Synonyms:
  • Tetrakis(4-tert-butylphenyl)boron potassium
  • POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE
CAS:
401818-78-8
MF:
C40H52BK
MW:
582.75
Mol File:
Mol File
More
Less

POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE Chemical Properties

Melting point:
≥300 °C
CAS DataBase Reference
401818-78-8
More
Less

Safety Information

Hazard Codes 
Xi
Risk Statements 
36/37/38
Safety Statements 
26-36
WGK Germany 
3
10

MSDS

More
Less

POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE Usage And Synthesis

Uses

It can be used to prepare enantiomeric potential sensors based on potassium tetrakis(4-tert-butylphenyl)borate. It can be used for the identification and detection between two enantiomers.

Application

CN201310686828 reports an enantiomeric potentiometer based on potassium tetra(4-tert-butylphenyl)borate, which is prepared by the following steps: (1) Weigh 3-4 parts by weight of potassium tetra(4-tert-butylphenyl)borate, 64-66 parts by weight of plasticizer and 32-33 parts by weight of PVC, and dissolve them in 600 parts by weight of tetrahydrofuran; (2) After all components are completely dissolved, pour the solution onto a glass plate and allow it to spread naturally. After standing at room temperature for 23-25 hours, a PVC film is obtained; (3) The obtained PVC film is... The membrane was attached to one end of a PVC hollow tube with a PVC concentration of 8% tetrahydrofuran solution. After 10 minutes, the solvent was completely evaporated and KCl was poured into the tube. An Ag/AgCl internal reference electrode was inserted to obtain a PVC membrane electrode. (4) The PVC membrane electrode and the calomel electrode were combined to form an enantiomeric potential sensor. The sensor expression is as follows: Hg-Hg2Cl2︱KCl(satd.)|test solution︱PVC membrane︱0.1mol·L-1KCl|AgCl-Ag.

POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATESupplier

Tianjin heowns Biochemical Technology Co., Ltd.
Tel
400 638 7771
Email
sales@heowns.com
Tianjin heowns Biochemical Technology Co., Ltd.
Tel
400-6387771-6039 18920764717
Email
sales@heowns.com
Zhengzhou convergence chemical co., LTD
Tel
0371-0371-55153829 18003835034
Email
2853979819@qq.com
Guangdong wengjiang Chemical Reagent Co., Ltd.
Tel
0751-2815987 13927875076
Email
3007432263@qq.com
Santa Cruz Biotechnology Inc
Tel
021-60936350
Email
scbt@scbt.com