Copper naphthenate(1338-02-9)
Product Identification
Product Name
Copper naphthenate
Synonyms
Cunap
Cunapsol 5
Cuprinol green
Naphthenic acid, copper salt
Naphthex Cu
Redycoat
CAS
1338-02-9
EINECS
215-657-0
RTECS
QK9100000
RTECS Class
Agricultural Chemical and Pesticide
Beilstein/Gmelin
NA
EC Index Number
029-003-00-5
EC Class
Flammable; Harmful; Dangerous for the Environment
Handling and Storage
Storage
Keep in well ventilated area keep away from heat.
Handling
All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.
Hazards Identification
Inhalation
Metal fume fever, wheezing and rales have been reported in workers exposed to fine copper dust. Dyspnea has developed after oral copper exposure. Pulmonary edema and alveolar inflammation have been noted in animals.
Skin
Skin exposure can produce in severe irritation, itching, erythema, dermatitis and eczema; systemic toxicity may result.
Eyes
Redness.
Ingestion
Gastroenteritis with vomiting may occur after ingestion of some copper salts. Mucosal erosions, a metallic taste, burning epigastric sensation and diarrhea may also occur.
Hazards
Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion and poison hazard indoors, outdoors or in sewers.
UN (DOT)
3009
Exposure Controls/Personal Protection
Personal Protection
Goggles or face shield; plastic gloves (as for gasoline).
Respirators
Wear positive pressure self-contained breathing apparatus (SCBA).
Exposure Effects
Increased temperature may be noted in some cases. Abnormally low blood pressure may occur. Mental status may be depressed.
Poison Class
5
Fire Fighting Measures
Autoignition
282
Fire Fighting
Do not extinguish fire unless flow can be stopped. Use water in flooding quantities as fog. Solid streams of water may be ineffective. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Use foam, dry chemical, or carbon dioxide.
Fire Potential
Moderately flammable.
ContactMore
- WebSite
- http://www.geeyeschem.com/15927657268/
- Tel
- 010-82848833
- Fax
- 86-10-82849933
- WebSite
- http://www.jkchemical.com
- Tel
- 021-61259108
- Fax
- 86-21-61259102
- WebSite
- https://www.meryer.com/cn/index/
- Tel
- 821-50328103-801
- Fax
- 86-21-50328109
- WebSite
- https://www.chemicalbook.com/ShowSupplierProductsList13285/0.htm
- Tel
- 400-1166-196
- Fax
- 028-84555506 800101999
- WebSite
- http://www.hx-r.com/