Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity Transport Information
Home > 2,3-Pentanedione > 2,3-Pentanedione(600-14-6)

2,3-Pentanedione(600-14-6)

Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity Transport Information
More
Less

Product Identification

Product Name

2,3-Pentanedione

Synonyms

Acetylpropionyl

CAS

600-14-6

Formula

C5H8O2

Molecular Weight

100.12

EINECS

209-984-8

RTECS

SA1850000

RTECS Class

Primary Irritant

Beilstein/Gmelin

1699638

Beilstein Reference

4-01-00-03660

EC Class

highly flammable

More
Less

Physical and Chemical Properties

Appearance

Clear, yellow liquid.

Solubility in water

Slightly soluble.

Melting Point

-52

Boiling Point

110

Vapor Pressure

214 (20 C)

Density

0.97 g/cm3 (18 C)

Vapor Density

3.45

Refractive Index

1.39918 (19 C)

More
Less

First Aid Measures

Ingestion

If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid immediately.

Inhalation

Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid.

Skin

Get medical aid. Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Remove contaminated clothing and shoes.

Eyes

Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid immediately.

More
Less

Handling and Storage

Storage

Keep away from heat, sparks, and flame. Keep away from sources of ignition. Store in a cool, dry, well-ventilated area away from incompatible substances. Refrigerator/flammables. Keep containers tightly closed.

Handling

Wash thoroughly after handling. Use with adequate ventilation. Ground and bond containers when transferring material. Use spark-proof tools and explosion proof equipment. Avoid contact with eyes, skin, and clothing. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Avoid contact with heat, sparks and flame. Avoid ingestion and inhalation. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose empty containers to heat, sparks or open flames.

More
Less

Hazards Identification

Inhalation

May cause respiratory tract irritation. Vapors may cause dizziness or suffocation.

Skin

Causes skin irritation and possible burns.

Eyes

May cause eye irritation and possible burns.

Ingestion

May cause digestive tract disturbances.

Hazards

Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.

EC Risk Phrase

R 11 36/37/38

EC Safety Phrase

S 16 26 36

UN (DOT)

1993

More
Less

Exposure Controls/Personal Protection

Personal Protection

Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to prevent skin exposure.

Respirators

Follow the OSHA respirator regulations found in 29CFR 1910.134 or European Standard EN 149. Always use a NIOSH or European Standard EN 149 approved respirator when necessary.

Exposure Effects

The toxological properties of this substance have not been fully investigated.

More
Less

Fire Fighting Measures

Flash Point

18

Autoignition

265

Fire Fighting

Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Will burn if involved in a fire. Use water spray to keep fire-exposed containers cool. Containers may explode in the heat of a fire. Extinguishing media: For small fires, use dry chemical, carbon dioxide, water spray or alcohol-resistant foam. For large fires, use water spray, fog, or alcohol-resistant foam. Water may be ineffective. Do NOT use straight streams of water. Cool containers with flooding quantities of water until well after fire is out.

Upper exp. limit

10.9

Lower exp. limit

1.8

Fire Potential

Flammable liquid.

More
Less

Accidental Release Measures

Small spills/leaks

Absorb spill with inert material, (e.g., dry sand or earth), then place into a chemical waste container. Avoid runoff into storm sewers and ditches which lead to waterways. Clean up spills immediately, using the appropriate protective equipment. Remove all sources of ignition. Use a spark-proof tool. Provide ventilation. A vapor suppressing foam may be used to reduce vapors. Water spray may reduce vapor but may not prevent ignition in closed spaces.

More
Less

Stability and Reactivity

Disposal Code

1

Stability

Stable under normal temperatures and pressures.

Incompatibilities

Strong oxidizing agents.

Decomposition

Carbon monoxide, carbon dioxide, acrid smoke and fumes.

Combustion Products

Fire may produce irritating, corrosive and/or toxic gases.

More
Less

Transport Information

UN Number

1993

Hazard Class

3

Packing Group

I; II; III

HS Code

2914 19 90

More
Less

ContactMore

Henan Wei Yuan Biotechnology Co., Ltd.
Tel
0371-27990887
Fax
0371-27536887
WebSite
https://www.iwysw.com/
Juye Zhongyue Spices Co., Ltd
Tel
0530-8599699
WebSite
http://www.zhongyuearoma.com
J & K SCIENTIFIC LTD.
Tel
18210857532;
Fax
86-10-82849933
WebSite
https://www.jkchemical.com
Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel
4006356688
Fax
86-21-61259102
WebSite
http://www.x-labseek.com/
Alfa Aesar
Tel
400-6106006
Fax
021-67582001/03/05
WebSite
http://chemicals.thermofisher.cn