Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity Transport Information
Home > 2,2-Dimethyl-propanoyl chloride > 2,2-Dimethyl-propanoyl chloride(3282-30-2)

2,2-Dimethyl-propanoyl chloride(3282-30-2)

Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity Transport Information
More
Less

Product Identification

Product Name

2,2-Dimethyl-propanoyl chloride

Synonyms

2,2-Dimethylpropanoyl chloride
Pivaloyl chloride

CAS

3282-30-2

Formula

C5H9ClO

Molecular Weight

120.58

EINECS

221-921-6

Beilstein/Gmelin

385668

Beilstein Reference

4-02-00-00912

EC Class

highly flammable, corrosive

More
Less

Physical and Chemical Properties

Appearance

Colorless fuming liquid with a pungent odor.

Solubility in water

Reacts

Melting Point

-56

Boiling Point

105

Vapor Pressure

100 (20 C)

Density

0.979 g/cm3 (20 C)

Partition Coefficient

2.19

Vapor Density

4.2

Refractive Index

1.4139 (20 C)

More
Less

First Aid Measures

Ingestion

Do NOT induce vomiting. If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid immediately.

Inhalation

Get medical aid immediately. Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. DO NOT use mouth-to-mouth respiration.

Skin

Get medical aid immediately. Immediately flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. Destroy contaminated shoes.

Eyes

Get medical aid immediately. Do NOT allow victim to rub or keep eyes closed. Extensive irrigation is required (at least 30 minutes).

More
Less

Handling and Storage

Storage

Keep away from heat, sparks, and flame. Keep away from sources of ignition. Keep container closed when not in use. Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances. Flammables-area.

Handling

Ground and bond containers when transferring material. Use spark-proof tools and explosion proof equipment. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Keep container tightly closed. Avoid contact with heat, sparks and flame. Do not get on skin or in eyes. Do not ingest or inhale. Use with adequate ventilation. Discard contaminated shoes. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose empty containers to heat, sparks or open flames.

More
Less

Hazards Identification

Ingestion

May cause severe and permanent damage to the digestive tract. Causes gastrointestinal tract burns.

Inhalation

May cause severe irritation of the respiratory tract with sore throat, coughing, shortness of breath and delayed lung edema. Causes chemical burns to the respiratory tract. Vapors may cause dizziness or suffocation.

Skin

Causes skin burns.

Eyes

Causes eye burns.

Hazards

May be ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. May polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water.

EC Risk Phrase

R 11 22 23 34

EC Safety Phrase

S 16 26 36/37/39 45

UN (DOT)

2438

More
Less

Exposure Controls/Personal Protection

Personal Protection

Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to prevent skin exposure.

Respirators

A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator's use. Follow the OSHA respirator regulations found in 29CFR 1910.134 or European Standard EN 149. Always use a NIOSH or European Standard EN 149 approved respirator when necessary.

Poison Class

4

More
Less

Fire Fighting Measures

Flash Point

14

Autoignition

455

Fire Fighting

Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Will burn if involved in a fire. Use water spray to keep fire-exposed containers cool. Containers may explode in the heat of a fire. Extinguishing media: For small fires, use dry chemical, carbon dioxide, water spray or alcohol-resistant foam. For large fires, use water spray, fog, or alcohol-resistant foam. Do NOT use water directly on fire. Use water spray to cool fire-exposed containers. Water may be ineffective. Do NOT use straight streams of water.

Upper exp. limit

7.4

Lower exp. limit

1.9

Fire Potential

Flammable/combustible material.

More
Less

Accidental Release Measures

Small spills/leaks

Absorb spill with inert material, (e.g., dry sand or earth), then place into a chemical waste container. Clean up spills immediately, using the appropriate protective equipment. Remove all sources of ignition. Use a spark-proof tool. Provide ventilation. A vapor suppressing foam may be used to reduce vapors.

More
Less

Stability and Reactivity

Disposal Code

11

Stability

Stable under normal temperatures and pressures.

Incompatibilities

Strong oxidizing agents.

Decomposition

Hydrogen chloride, phosgene, carbon monoxide, carbon dioxide.

Combustion Products

Fire will produce irritating, corrosive and/or toxic gases.

More
Less

Transport Information

UN Number

2438

Hazard Class

6.1

Packing Group

I

HS Code

2915 90 80

More
Less

ContactMore

Nanjing Vital Chemical Co., Ltd.
Tel
025-87193546
Fax
025-87193546
WebSite
https://www.chemicalbook.com/supplier/10520562/
Shanghai Aladdin Bio-Chem Technology Co.,LTD
Tel
400-6206333
Fax
021-50323701
WebSite
http://www.aladdin-e.com/
Beijing Tianyukanghong Chemical Technology Co., Ltd.
Tel
010-57794770
Fax
010-60593781
WebSite
http://www.tykhchem.com
Tianjin Zhongxin Chemtech Co., Ltd.
Tel
022-66880623
Fax
86(0)22-66880086
WebSite
http://www.tjzxchem.com
Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel
4006608290;
Fax
86-21-61259102
WebSite
https://www.meryer.com/cn/index/