Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity
Home > 5-Dodecanolide > 5-Dodecanolide(713-95-1)

5-Dodecanolide(713-95-1)

Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity
More
Less

Product Identification

Product Name

5-Dodecanolide

Synonyms

5-Hydroxydodecanoic acid delta-lactone
5-Hydroxydodecanoic acid lactone
6-Heptyloxan-2-one
delta-Dodecalactone
n-Heptyl-delta-valerolactone

CAS

713-95-1

Formula

C12H22O2

Molecular Weight

198.34

EINECS

211-932-4

RTECS

UQ0850000

RTECS Class

Primary Irritant

Beilstein/Gmelin

1282749

Beilstein Reference

5-17-09-00100

More
Less

Physical and Chemical Properties

Melting Point

-7

Boiling Point

126 - 128 (0.5 torr)

Density

0.9585 g/cm3 (20 C)

Usage

Flavor chemical.

Refractive Index

1.46 (20 C)

More
Less

First Aid Measures

Ingestion

Emesis is not indicated due to the irritant nature of these agents. Charcoal - not recommended; it may promote vomiting and make endoscopic evaluation difficult. Immediately dilute with 4 to 8 ounces (120 to 240 ml) of milk or water (not to exceed 4 ounces/120 ml in a child). Neutralization - neutralization is not indicated. Although these agents are irritants, and therefore should not produce tissue damage, it is almost impossible to assure that a particular substance under a particular set of circumstances would not cause damage. Therefore, each patient should be examined with the idea that mucous membrane damage might have occurred.

Inhalation

Move patient to fresh air. Monitor for respiratory distress. If cough or difficulty breathing develops, evaluate for respiratory tract irritation, bronchitis, or pneumonitis. Administer oxygen and assist ventilation as required. Treat bronchospasm with beta2 agonist and corticosteroid aerosols.

Skin

Remove contaminated clothing. Wash exposed area with soap and water. If symptoms persist, seek medical attention. Launder clothing before reuse.

Eyes

Irrigate exposed eyes with copious amounts of tepid water for at least 15 minutes. If irritation, pain, swelling, lacrimation, or photophobia persist, the patient should be seen in a health care facility. If in a medical facility, sterile saline should be used to irrigate the eyes until the cul de sac is returned to neutrality. Some alkali exposures may require prolonged irrigation.

More
Less

Handling and Storage

Storage

Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.

Handling

All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.

More
Less

Hazards Identification

Ingestion

Nausea, vomiting and diarrhea are possible if ingested.

Inhalation

Cough, tachypnea, and wheezing are common after inhalation.

Skin

Redness, swelling and pain may occur.

EC Risk Phrase

R 36/38

EC Safety Phrase

S 26 36

More
Less

Exposure Controls/Personal Protection

Personal Protection

Chemical splash goggles in compliance with OSHA regulations are advised; however, OSHA regulations also permit other type safety glasses. Whre chemical resistant gloves. To prevent repeated or prolonged skin contact, wear impervious clothing and boots.

Respirators

Use NIOSH/MSHA approved respirator appropriate for exposure of concern.

More
Less

Fire Fighting Measures

Flash Point

165

Fire Fighting

Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Use agent most appropriate to extinguish fire.

More
Less

Accidental Release Measures

Small spills/leaks

Evacuate area and ventilate. Wear protective equipment. If required, use an inert absrobent. Sweep up and place in an appropriate container for disposal. Wash contaminated surfaces.

More
Less

Stability and Reactivity

Stability

No data.

Incompatibilities

Strong oxidizing agents.

More
Less

ContactMore

Chengdu Dianchun Technology Co., Ltd
Tel
400-1166-196
Fax
QQ:800101999
WebSite
http://www.hx-r.com
J & K SCIENTIFIC LTD.
Tel
010-82848833
Fax
86-10-82849933
WebSite
http://www.jkchemical.com
Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel
021-61259108
Fax
86-21-61259102
WebSite
https://www.meryer.com/cn/index/
Alfa Aesar
Tel
400-6106006
Fax
021-67582001/03/05
WebSite
http://chemicals.thermofisher.cn
TCI (Shanghai) Development Co., Ltd.
Tel
021-67121386
Fax
021-67121385
WebSite
https://www.tcichemicals.com/CN/zh/