Product Identification

Product Name

Ferric hydroxide dextran complex

Synonyms

Chinofer
Dextran iron complex
Dextrofer 75
Fenate
Ferdex 100
Ferric dextran

CAS

9004-66-4

RTECS

NI2200000

RTECS Class

Tumorigen; Drug; Reproductive Effector; Human Data

Beilstein/Gmelin

NA

More
Less

Physical and Chemical Properties

Appearance

Dark reddish-brown liquid.

Solubility in water

extremely soluble

Usage

Medication.

More
Less

First Aid Measures

Ingestion

Seek medical attention. If individual is drowsy or unconscious, do not give anything by mouth; place individual on the left side with the head down. Contact a physician, medical facility, or poison control center for advice about whether to induce vomiting. If possible, do not leave individual unattended.

Inhalation

IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. IMMEDIATELY call a physician and be prepared to transport the victim to a hospital even if no symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used.

Skin

IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. If symptoms such as redness or irritation develop, IMMEDIATELY call a physician and be prepared to transport the victim to a hospital for treatment.

Eyes

First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.

More
Less

Handling and Storage

Storage

Storage location should be close to laboratory where it is to be used, so that only small amounts need to be transported. Carcinogens should be kept in only one section of storage area, explosion-proof refrigerator or freezer as required. The area should be appropriately labeled. An inventory should be kept showing the quantity of carcinogen and date it was acquired. Facilities for dispensing should be contiguous to storage area.

Handling

All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.

More
Less

Hazards Identification

Inhalation

Dyspnea and bronchospasm have been reported with iron dextran and appear related to an anaphylactic response.

Skin

Urticaria, pruritus, purpura and skin discoloration have been reported following the use of iron dextran.

Ingestion

Gastrointestinal symptoms (e.g., nausea, vomiting, diarrhea) have been reported .

More
Less

Exposure Controls/Personal Protection

Personal Protection

Dispensers of liquid detergent should be available. In the laboratory, gloves and protective clothing should always be worn but should not be assumed to provide full protection. Carefully fitted masks or respirators may be necessary when working with particulates or gases, and disposable plastic aprons might provide additional protection. Protective clothing should be of distinctive color, as a reminder not to be worn outside the laboratory.

Respirators

Wear a NIOSH-approved half face respirator equipped with an organic vapor/acid gas cartridge (specific for organic vapors, HCl, acid gas and SO2) with a dust/mist filter.

Exposure Effects

dizziness and headache have been reported, along with a cluster of other symptoms, 1 to 2 days after administration.

More
Less

Fire Fighting Measures

Fire Fighting

Fires involving this material can be controlled with a dry chemical, carbon dioxide or Halon extinguisher.

Fire Potential

This chemical is combustible.

More
Less

Accidental Release Measures

Small spills/leaks

If you spill this chemical, FIRST REMOVE ALL SOURCES OF IGNITION. Then, use absorbent paper to pick up all liquid spill material. Seal the absorbent paper, as well as any of your clothing which may be contaminated, in a vapor-tight plastic bag for eventual disposal. Wash any surfaces you may have contaminated with a soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned.

More
Less

Stability and Reactivity

Stability

Complex is unstable @ pH 5; it does not undergo autoxidation @ ambient temperature, but this does occur @ 65-70 C. Expiration date of 5 yr following date of mfr.

Incompatibilities

Sensitive to prolonged exposure to air.

More
Less

ContactMore

Guangxi TG Pharmaceutical Co., Ltd
Tel
0771-4844990
Fax
+86-771-4844775
WebSite
https://www.chemicalbook.com/ShowSupplierProductsList19488/0.htm
Wuhan Runzeweiye Technology Co., Ltd.
Tel
15172337137
Fax
027-50779735
WebSite
https://www.chemicalbook.com/ShowSupplierProductsList20046/0.htm
J & K SCIENTIFIC LTD.
Tel
010-82848833
Fax
86-10-82849933
WebSite
http://www.jkchemical.com
ShangHai DEMO Chemical Co.,Ltd
Tel
400-021-7337 2355568890
Fax
0086-21-50182339
WebSite
http://www.demochem.com
Chemsky(shanghai)International Co.,Ltd.
Tel
021-50135380
WebSite
http://www.shchemsky.com