Supplier Product Identification Physical and Chemical Properties First Aid Measures Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Transport Information Stability and Reactivity
Home > 2,3,5-Trifluoropyridine > 2,3,5-Trifluoropyridine(76469-41-5)

2,3,5-Trifluoropyridine(76469-41-5)

Supplier Product Identification Physical and Chemical Properties First Aid Measures Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Transport Information Stability and Reactivity
More
Less

Product Identification

Product Name

2,3,5-Trifluoropyridine

CAS

76469-41-5

Formula

C5H2F3N

Molecular Weight

133.07

Beilstein/Gmelin

NA

More
Less

Physical and Chemical Properties

Boiling Point

102

Density

1.499 g/cm3 (20 C)

Refractive Index

1.42 (20 C)

More
Less

First Aid Measures

Ingestion

Seek medical assistance.

Inhalation

Move victim to fresh air. Apply artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult.

Skin

Remove and isolate contaminated clothing and shoes. Wash skin with soap and water. Flush with running water for at least 20 minutes

Eyes

Flush with running water for at least 20 minutes.

More
Less

Hazards Identification

Inhalation

Vapors may cause dizziness or suffocation. May cause irritation or burns.

Skin

May cause irritation or burns.

Eyes

See Skin.

Hazards

Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.

EC Risk Phrase

R 10 36/37/38

EC Safety Phrase

S 23 26 36

UN (DOT)

1993

More
Less

Exposure Controls/Personal Protection

Personal Protection

Wear appropriate protective gloves, clothing and goggles.

Respirators

Wear positive pressure self-contained breathing apparatus (SCBA).

More
Less

Fire Fighting Measures

Flash Point

30

Fire Fighting

Use of water spray when fighting fire may be inefficient. Small Fires: Dry chemical, carbon dioxide, water spray or alcohol-resistant foam. Large Fires: Water spray, fog or alcohol-resistant foam. Use water spray or fog; do not use straight streams.

Fire Potential

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.

More
Less

Accidental Release Measures

Small spills/leaks

Make no contact with the spilled material. ELIMINATE all ignition sources and ground all equipment. Stop leak if you can do it without risk. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material.

More
Less

Transport Information

UN Number

1993

More
Less

Stability and Reactivity

Combustion Products

Fire may produce irritating, corrosive and/or toxic gases.

More
Less

ContactMore

Sino-Biochemical Laboratory Co., Ltd.
Tel
21-21-31590156
Fax
+86 21 31590152
WebSite
http://www.sino-biochemlab.com
Jiangsu Luheng Biomedical Co., Ltd.
Tel
18912923751;
WebSite
https://www.chemicalbook.com/ShowSupplierProductsList1510349/0.htm
J & K SCIENTIFIC LTD.
Tel
010-82848833
Fax
86-10-82849933
WebSite
http://www.jkchemical.com
Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel
021-61259108
Fax
86-21-61259102
WebSite
https://www.meryer.com/cn/index/
INTATRADE GmbH
Tel
+49 3493/605464
Fax
+49 3493/605470
WebSite
http://www.intatrade.de/